BrachyVision? 8.5
1 / 7Páginas

Excertos do catálogo

BrachyVision? 8.5 - 1

VARIAN BRACHYTHERAPY | INFORM PLAN VERIFY TREAT BrachyVision Treatment Planning

Abrir o catálogo na página 1
BrachyVision? 8.5 - 2

Expect more with BrachyVision The new paradigm for image-based planning BrachyVision™ is a complete 3D treatment planning system that introduces a new paradigm of patient-centric, image-based planning. Optimized for use with Varian’s VariSource™ iX and GammaMedplus™ iX HDR afterloader products, BrachyVision meets all of your brachytherapy planning needs. As part of the ARIA™ oncology information system family, BrachyVision oers a common interface for users of Varian systems. BrachyVision oers: • Integration with the Eclipse™ treatment planning system supporting a combined database, patient...

Abrir o catálogo na página 2
BrachyVision? 8.5 - 3

Complete brachytherapy planning system BrachyVision is a complete treatment planning system that allows plans to be generated for LDR, PDR, and HDR treatments using coordinates, lms, or 3D images. Image acquisition Ideally suited for accelerated prostate brachytherapy Combined with the advanced capabilities of BrachyVision, Vitesse™ real-time HDR brachytherapy allows 3D HDR prostate brachytherapy to be performed accurately and quickly without the need for CT. The exibility of BrachyVision allows the user to acquire images • Using DICOM 3.0 • Directly from an ARIA server Image registration...

Abrir o catálogo na página 3
BrachyVision? 8.5 - 4

Extensive set of tools to meet every need Powerful contour editing Delineate target volumes structures on any plane. Plan data from localization radiographs For image-guided brachytherapy (IGBT), segmenting organs at risk and precisely delineating target volumes are critical and time-consuming tasks. BrachyVision uses the same extensive set of tools found in Eclipse to reduce this time from hours to minutes. Clinicians can accurately dene target and critical structures on fused multi-modality images with advanced drawing and editing capabilities. Enhanced templates and powerful...

Abrir o catálogo na página 4
BrachyVision? 8.5 - 5

Planning with the latest technology Multiple dose optimization methods BrachyVision provides a variety of dose optimization methods which may be used alone or in combination to obtain the optimal dose plan. Adaptive volume optimization (AVOL) Manual dose optimization Dose Shaper™ graphical interactive optimization provides inverse visual planning Adaptive volumetric optimization introduces options to the existing inverse planning tool to get the plan you want — the rst time, every time. The optimization routine attempts to match the specied DVH limits to structures (or lines) while creating...

Abrir o catálogo na página 5
BrachyVision? 8.5 - 6

Intuitive plan evaluation Analyze and compare alternative plans Technical specications Use the plan evaluation workspace for analyzing and comparing alternative plans to determine the most appropriate plan for treatment. Compare plans side by side, or sum and evaluate matched image sets. View DVHs on the same graph for both multiple and summed plans. Stand alone workstations Software • HDR brachytherapy planning • DICOM-3 network image data interface Hardware (conguration to be as follows or better) Tower system • LDR brachytherapy planning • Template-based pre-plans BrachyVision creates an...

Abrir o catálogo na página 6
BrachyVision? 8.5 - 7

Varian Medical Systems Oncology Systems 3100 Hansen Way Palo Alto, CA 94304-1038 Tel: 650.424.5700 | Tel: 800.544.4636 http://www.varian.com For more information on BrachyVision, visit http://www.varian.com/brachytherapy. USA Headquarters California Varian Medical Systems Palo Alto, CA Tel: 650.424.5700 800.544.4636 Fax: 650.493.5637 www.varian.com BrachyTherapy Offices USA Varian Medical Systems BrachyTherapy Head Office Charlottesville, VA Tel: 888.666.7847 Fax: 434.244.7181 UK Varian Medical Systems UK Ltd. BrachyTherapy Crawley, West Sussex, UK Tel: 44.1293.601.219 Fax: 44.1293.542.626...

Abrir o catálogo na página 7

Todos os catálogos e folhetos técnicos Varian Oncology

  1. Halcyon

    15 Páginas

  2. Eclipse

    7 Páginas

  3. TrueBeam Brochure

    11 Páginas

  4. ProBeam Brochure

    16 Páginas

Catálogos arquivados

  1. Trilogy Brochure

    7 Páginas

  2. VitalBeam

    8 Páginas

  3. HyperArc Overview

    2 Páginas

  4. Eclipse™

    2 Páginas

  5. ProBeam 360

    2 Páginas

  6. VELOCITY SOFTWARE

    3 Páginas

  7. 360 ONCOLOGY

    3 Páginas

  8. HALCYON

    12 Páginas

  9. PaxScan ® 3030X

    2 Páginas

  10. PaxScan ® 4336X

    4 Páginas

  11. PaxScan ® 4343R

    2 Páginas

  12. Nexus-DRF™

    2 Páginas

  13. 2520DX

    2 Páginas

  14. 1515DXT

    2 Páginas

  15. PaxScan 1508 DXT

    2 Páginas

  16. PaxScan 1313DXT

    2 Páginas

  17. 1308DXT

    2 Páginas

  18. Clinac Brochure

    12 Páginas

  19. Edge Brochure

    22 Páginas

  20. NDI-452

    4 Páginas

  21. M-101G

    6 Páginas

  22. M-105SP

    6 Páginas

  23. M-109

    6 Páginas

  24. M-113

    6 Páginas

  25. M-143

    6 Páginas

  26. M-147SP

    6 Páginas

  27. M-146

    6 Páginas

  28. M-147

    6 Páginas

  29. RAD-85S

    6 Páginas

  30. M-149

    6 Páginas

  31. M-151

    10 Páginas

  32. M-152

    12 Páginas

  33. M-153

    8 Páginas

  34. PaxScan 3030+

    2 Páginas

  35. M-171

    6 Páginas

  36. PaxScan 2520E+

    2 Páginas

  37. PaxScan 4030E

    2 Páginas

  38. PaxScan 4336R

    2 Páginas

  39. PaxScan® 2020X

    2 Páginas

  40. PaxScan® 2020+

    2 Páginas

  41. 1313

    2 Páginas

  42. PaxScan® 1308

    2 Páginas

  43. Vitesse 3.0

    3 Páginas

  44. BrachyVision

    7 Páginas

  45. RapidArc

    8 Páginas

  46. PaxScan ® 4030CB

    2 Páginas

  47. PaxScan ® 1313DX

    2 Páginas

  48. PaxScan ® 1308DX

    2 Páginas

  49. Vitesse? 2.5

    2 Páginas

  50. Varian BrachyTherapy

    147 Páginas