M-152
1 / 12Páginas

Excertos do catálogo

M-152 - 1

X-RAY PRODUCTS Rotating Anode X-Ray Tube Tubes Radiogénes à Anode Tournante Röntgenröhre mit Rotierender Anode Tubos de Rayos-X con Ánodo Giratorio Note: Document originally drafted in the English language. Product Description The M-152 is a 2.75” (70 mm) 49.0 kV, 97 kJ (135 kHU) maximum anode heat content, rotating anode insert. This insert is specifically designed for use in Mammography systems. The insert features two targets, one of Molybdenum and the other Rhodium and is available with the following nominal focal spots: Description du Produit Le tube M-152, à anode tournante de 70 mm, (2,75 pouces) de 49,0 kV et une capacité calorifique maximale de 97 kJ (135 kUC) est à usage spécifique pour la mammography. L'insertion comporte deux cibles, une de molybdène et l'autre rhodium et est disponible avec les taches focales nominales suivantes : Nominal Anode Input Power Small (Mo) - 2.5 kW IEC 60613 Large (Mo) - 5.5 kW IEC 60613 Small (Rh) - 2.0 kW IEC 60613 Large (Rh) - 4.1 kW IEC 60613 For the equivalent anode input power of 80 Watts Puissance Nominale de l’anode Petit (Mo) - 2.5 kW CEI 60613 Grand (Mo) - 5.5 kW CEI 60613 Petit (Rh) - 2.0 kW CEI 60613 Grand (Rh) - 4.1 kW CEI 60613 Pour la puissance anodique d’equilibre thermique de 80 Watts This insert is intended for use in M52.2 housings. Ce tube est destiné à être inséré dans le gaine M52.2. All trademarks property of the respective manufacturer Toute la propriété de marques déposées du fabricant respectif Produktbeschreibung Die M-152 ist eine 70 mm (2.75”) Doppelfokus DrehanodenRöntgenröhre, mit einer Wärmespeicherkapazität des Anodentellers von 97 kJ (135 kHU) und einer max. Spannungsfestigkeit von 49.0 kV. Diese Röhre findet ihren speziellen Einsatz in Mammographie Röntgensystemen. Den Einsatz kennzeichnen zwei Anoden, mit Molybdän und bzw. Rhodium. Folgende nominalen Brennflecke ist verhügbar: Descripcion del Producto El M-152 es un tubo de ánodo giratorio de 70 mm (2.75”), 49.0 kV, 97 kJ (135 kUH) diseñado especificamente para uso en el sistema de mamografia. El inserto ofrece dos pistas, una de molibdeno, la otro de rodio y está disponible con los siguientes focales: El Poder de Penetracion Para del Anodo Nominal Pequeño (Mo) - 2.5 kW IEC 60613 Grande (Mo) - 5.5 kW IEC 60613 Pequeño (Rh) - 2.0 kW IEC 60613 Grande (Rh) - 4.1 kW IEC 60613 Para una potencia equivalente del anodo de 80 Watts Nominale Anoden Eingangsleistung Klein (Mo) - 2.5 kW IEC 60613 Gross (Mo) - 5.5 kW IEC 60613 Klein (Rh) - 2.0 kW IEC 60613 Gross Rh) - 4.1 kW IEC 60613 Gilt bei einer Aquivalent Anodenleistung von 80 Watt Die Röntgenröhre ist für den Einbau in die Strahlerhaube M52.2 vorgesehen. Este tubo es diseñado, para uso en el encaje de la M52.2. Toda la característica de las marcas registradas del fabricante respectivo Alle Warenzeicheneigenschaft des jeweiligen Herstellers Manufactured by Varian Medical Systems Fabrique par Varian Medical Systems Hergestellt von Varian Medical Systems Fabricado por Varian Medical Systems Specifications subject to change without notice. Spécifications susceptibles d’être modifiées sans préavis. Technische Daten ohne Gewähr. Especificaciones sujetas a cambio sin previo aviso.

Abrir o catálogo na página 1
M-152 - 2

medical systems Tube Outline Drawing Dessin d'Encombrement de la Tube Esquema Detallado del Tubos TUBE BIAS- Copyright © 2012, Varian Medical Systems. All Rights Reserved.

Abrir o catálogo na página 2
M-152 - 3

medical systems Filament Emission Charts IEC 60613 THREE PHASE EMISSION (± .15 A) THREE PHASE EMISSION (± .15 A) Abaques d' Emissions des Filaments CEI 60613 Curvas de Emision de los Filamentos IEC 60613 THREE PHASE EMISSION (± .15 A) THREE PHASE EMISSION (± .15 A) Note: When using these emission curves for trial exposures, refer to the power rating curves shown for maximum kV, tube emission, filament current, exposure time, and target speed. Remarque: Lors de l'utilisation de ces abaques pour des expositions d'essai, referez-vous aux courbes maximales de kV, d'emission du filament, de...

Abrir o catálogo na página 3
M-152 - 4

medical systems Single Load Ratings IEC 60613 Abaques de Chargepour Pose Unique CEI 60613 Diagramas de Exposition Radiografica IEC 60613 NOMINAL FOCAL SPOT SIZE - 0.3 Copyright © 2012, Varian Medical Systems. All Rights Reserved.

Abrir o catálogo na página 4
M-152 - 5

medical systems Single Load Ratings IEC 60613 Abaques de Chargepour Pose Unique CEI 60613 Diagramas de Exposicion Radiografica IEC 60613 NOMINAL FOCAL SPOT SIZE - 0.3 MAXIMUM EXPOSURE TIME (SECONDS) NOMINAL FOCAL SPOT SIZE - 0.1 NOMINAL FOCAL SPOT SIZE - 0.3 MAXIMUM EXPOSURE TIME (SECONDS) MAXIMUM EXPOSURE TIME (SECONDS) Copyright © 2012, Varian Medical Systems. All Rights Reserved.

Abrir o catálogo na página 5
M-152 - 6

X-RAY PRODUCTS Tube Unit Description Product Description Maximum Potential Difference Cathode to Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 kV Anode to Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 kV Diffèrence de potentiel maximum Entre Cathode et Masse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 kV Entre Anode et Masse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 kV Heat Storage Capacity . . . . . . . . . . . . . . . . . . . . . . . . . ....

Abrir o catálogo na página 6
M-152 - 7

X-RAY PRODUCTS Dessin d’ Encombrement de la Gaine Tube Unit Outline Drawing Copyright © 2012, Varian Medical Systems. All Rights Reserved. Esquema Detallado del Encaje

Abrir o catálogo na página 7
M-152 - 8

medical systems Tube Assembly Heating and Cooling Rohrengehausebaugruppe Aufheizung und Abkuhlung Enfriamiento y Calentamiento del Encaje Asamblado HOUSING ASSEMBLY HEATING AND COOLING Time (Minutes) Duree (Minutes) Zeit (Minuten) Tiempo (Minutos) Heat inputs include tube power, filament power, and stator power. Heating curves based on no restrictions of natural convection around tube unit assembly. L'chaleur introduite dans la gaine tient compte de la puissance du tube, du filament et du stator. Les courbes d'echauffement ne supposent aucune restriction de la convection naturelle autour de...

Abrir o catálogo na página 8

Todos os catálogos e folhetos técnicos Varian Oncology

  1. Halcyon

    15 Páginas

  2. Eclipse

    7 Páginas

  3. TrueBeam Brochure

    11 Páginas

  4. ProBeam Brochure

    16 Páginas

Catálogos arquivados

  1. Trilogy Brochure

    7 Páginas

  2. VitalBeam

    8 Páginas

  3. HyperArc Overview

    2 Páginas

  4. Eclipse™

    2 Páginas

  5. ProBeam 360

    2 Páginas

  6. VELOCITY SOFTWARE

    3 Páginas

  7. 360 ONCOLOGY

    3 Páginas

  8. HALCYON

    12 Páginas

  9. PaxScan ® 3030X

    2 Páginas

  10. PaxScan ® 4336X

    4 Páginas

  11. PaxScan ® 4343R

    2 Páginas

  12. Nexus-DRF™

    2 Páginas

  13. 2520DX

    2 Páginas

  14. 1515DXT

    2 Páginas

  15. PaxScan 1508 DXT

    2 Páginas

  16. PaxScan 1313DXT

    2 Páginas

  17. 1308DXT

    2 Páginas

  18. Clinac Brochure

    12 Páginas

  19. Edge Brochure

    22 Páginas

  20. NDI-452

    4 Páginas

  21. M-101G

    6 Páginas

  22. M-105SP

    6 Páginas

  23. M-109

    6 Páginas

  24. M-113

    6 Páginas

  25. M-143

    6 Páginas

  26. M-147SP

    6 Páginas

  27. M-146

    6 Páginas

  28. M-147

    6 Páginas

  29. RAD-85S

    6 Páginas

  30. M-149

    6 Páginas

  31. M-151

    10 Páginas

  32. M-153

    8 Páginas

  33. PaxScan 3030+

    2 Páginas

  34. M-171

    6 Páginas

  35. PaxScan 2520E+

    2 Páginas

  36. PaxScan 4030E

    2 Páginas

  37. PaxScan 4336R

    2 Páginas

  38. PaxScan® 2020X

    2 Páginas

  39. PaxScan® 2020+

    2 Páginas

  40. 1313

    2 Páginas

  41. PaxScan® 1308

    2 Páginas

  42. Vitesse 3.0

    3 Páginas

  43. BrachyVision

    7 Páginas

  44. RapidArc

    8 Páginas

  45. PaxScan ® 4030CB

    2 Páginas

  46. PaxScan ® 1313DX

    2 Páginas

  47. PaxScan ® 1308DX

    2 Páginas

  48. Vitesse? 2.5

    2 Páginas

  49. BrachyVision? 8.5

    7 Páginas

  50. Varian BrachyTherapy

    147 Páginas