Proton Beam Therapy Treatment Techniques
1 / 4Páginas

{{requestButtons}}

Excertos do catálogo

Proton Beam Therapy Treatment Techniques - 1

Proton Therapy System PROTON BEAM THERAPY SCATTERING VERSUS SCANNING TREATMENT TECHNIQUES Protons have potential advantages over photons for delivering higher radiation doses to the tumor while sparing the surrounding healthy tissue. Though protons are inherently capable of higher dose conformity and lower integral dose to the body, the method of proton beam delivery is an important consideration as well. Beam delivery methods Two proton beam delivery methods are available today: passive spreading, which includes single and dual scattering, and active spreading, which is commonly known as scanning. In passive spreading techniques, the proton beam is spread by placing scattering material in its path. A single scatterer broadens the beam sufficiently for the coverage of small fields. For larger fields, a second scatterer is needed to ensure a uniform dose profile. A combination of custom-made collimators and compensators conform the dose to the target volume. The spread out Bragg peak (SOBP) used for treatment is obtained by a set of range modulator wheels or ridge filters inside the gantry of the delivery system. (See Figure 1.) In scanning beam techniques, magnets deflect and steer the proton beam. Under computer control, the beam “paints” the treatment volume, voxel by voxel, in successive layers. The depth of penetration of the Bragg peak is adjusted by varying the energy of the beam before it enters the gantry. (See Figure 2.) Patient Scatterer Modulator wheels or ridge filters Target Extra dose Scatterer (contoured) Figure 1: Scattering diagram Treatment volume Magnets Figure 2: Scanning diagr

Abrir o catálogo na página 1
Proton Beam Therapy Treatment Techniques - 2

SCATTERING VERSUS SCANNING AT A GLANCE How do these two delivery methods compare in a clinical setting? Are there differences in the conformity of the treatment, or the integral dose to patients? What should centers consider when choosing a proton therapy system? The following table addresses these questions through a side-by-side comparison of scattering versus scanning to help clinicians determine the most appropriate treatment method. SCANNING Beam modifying devices Dual scattering uses patient-specific beam-modifying devices to conform the dose to the treatment volume. These devices...

Abrir o catálogo na página 2
Proton Beam Therapy Treatment Techniques - 3

SCANNING IMPT With dual scattering, the ability to vary the dose distribution throughout the treatment volume is limited. Multiple fields can deposit dose from different directions. However, multiple fields require a complex set of compensators and apertures, and switching them adds to the treatment time. Scanning makes IMPT possible. With scanning, dose distributions can be varied voxel by voxel. By varying the beam intensity or the speed of the scan, or both, dose is painted non-uniformly on a field-by-field basis to yield an overall uniform target dose. The scanning technique lets...

Abrir o catálogo na página 3
Proton Beam Therapy Treatment Techniques - 4

Proton Therapy System VARIAN PROTON THERAPY Varian stakes its global reputation on giving patients and clinicians innovative treatment technology for fighting cancer. Our mission is to help save more lives, improve the quality of treatment, and provide solutions for treating a wide range of cancers. Proton therapy is one weapon in Varian’s advanced treatment arsenal, and we intend to drive its development forward as we have other modes of radiation treatment. Our pledge is this: when you want sophisticated, advanced treatments, you can turn to Varian. References Blom M, Glimelius B, Lorin...

Abrir o catálogo na página 4

Todos os catálogos e folhetos técnicos Varian Oncology

  1. Halcyon

    15 Páginas

  2. Eclipse

    7 Páginas

  3. TrueBeam Brochure

    11 Páginas

  4. ProBeam Brochure

    16 Páginas

Catálogos arquivados

  1. Trilogy Brochure

    7 Páginas

  2. VitalBeam

    8 Páginas

  3. HyperArc Overview

    2 Páginas

  4. Eclipse™

    2 Páginas

  5. ProBeam 360

    2 Páginas

  6. VELOCITY SOFTWARE

    3 Páginas

  7. 360 ONCOLOGY

    3 Páginas

  8. HALCYON

    12 Páginas

  9. PaxScan ® 3030X

    2 Páginas

  10. PaxScan ® 4336X

    4 Páginas

  11. PaxScan ® 4343R

    2 Páginas

  12. Nexus-DRF™

    2 Páginas

  13. 2520DX

    2 Páginas

  14. 1515DXT

    2 Páginas

  15. PaxScan 1508 DXT

    2 Páginas

  16. PaxScan 1313DXT

    2 Páginas

  17. 1308DXT

    2 Páginas

  18. Clinac Brochure

    12 Páginas

  19. Edge Brochure

    22 Páginas

  20. NDI-452

    4 Páginas

  21. M-101G

    6 Páginas

  22. M-105SP

    6 Páginas

  23. M-109

    6 Páginas

  24. M-113

    6 Páginas

  25. M-143

    6 Páginas

  26. M-147SP

    6 Páginas

  27. M-146

    6 Páginas

  28. M-147

    6 Páginas

  29. RAD-85S

    6 Páginas

  30. M-149

    6 Páginas

  31. M-151

    10 Páginas

  32. M-152

    12 Páginas

  33. M-153

    8 Páginas

  34. PaxScan 3030+

    2 Páginas

  35. M-171

    6 Páginas

  36. PaxScan 2520E+

    2 Páginas

  37. PaxScan 4030E

    2 Páginas

  38. PaxScan 4336R

    2 Páginas

  39. PaxScan® 2020X

    2 Páginas

  40. PaxScan® 2020+

    2 Páginas

  41. 1313

    2 Páginas

  42. PaxScan® 1308

    2 Páginas

  43. Vitesse 3.0

    3 Páginas

  44. BrachyVision

    7 Páginas

  45. RapidArc

    8 Páginas

  46. PaxScan ® 4030CB

    2 Páginas

  47. PaxScan ® 1313DX

    2 Páginas

  48. PaxScan ® 1308DX

    2 Páginas

  49. Vitesse? 2.5

    2 Páginas

  50. BrachyVision? 8.5

    7 Páginas

  51. Varian BrachyTherapy

    147 Páginas